Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Contemp Clin Trials Commun ; 38: 101260, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38384894

RESUMO

Introduction: Percutaneous coronary intervention with implantation of a bioresorbable scaffold (BRS) provide the vessel support for a limited period allowing the vessel to restore normal vasomotion after degradation of the BRS, opposed to treatment with drug-eluting stents where the metal persist in the vessel wall. Late lumen loss and reduction in lumen area after implantation have been reported. The purpose of this study was to investigate whether intense pre-dilatation before BRS implantation resulted in less reduction of minimal lumen area at 6- and 12-month follow-up after implantation of a Magmaris BRS (MgBRS). Coronary imaging with optical coherence tomography (OCT) and intravascular ultrasound (IVUS) was assessed to track changes in lumen and vessel dimensions. Methods: The prospective Optimal lesion PreparaTion before Implantation of the Magmaris bioresorbable scaffold In patients with coronary artery Stenosis (OPTIMIS) study randomly assigned eighty-two patients with chronic coronary syndrome to two pre-dilatation treatment strategies. Patients were randomized in a 1:1 ratio to pre-dilatation with either a non-compliant scoring balloon or a standard non-compliant balloon prior to implantation of a MgBRS. The treated segment was evaluated with OCT and IVUS at baseline, after 6 and 12 months to assess changes in lumen and vessel dimensions. The hypothesis was that more intense pre-dilatation with a non-compliant scoring balloon before MgBRS implantation can reduce the risk of late lumen reduction compared to standard pre-dilatation. The power calculation used expected MLA after 6 months (6.22 mm2 for the scoring balloon and 5.01 mm2 for the standard non-compliant balloon), power of 80 %, significance level of 0.05 and expected drop-out rate of 15 %, requiring 82 patients to be enrolled. Results: Eighty-two patients were included in the study. Enrollment was from December 2020 to September 2023. Conclusion: The hypothesis was that more intense pre-dilatation with a non-compliant scoring balloon before MgBRS implantation can reduce the risk of late lumen reduction compared to standard pre-dilatation.

2.
Coron Artery Dis ; 35(2): 92-98, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38009377

RESUMO

BACKGROUND: Cardiac 15 O-water PET is a noninvasive method to evaluate epicardial and microvascular dysfunction and further quantitate absolute myocardial blood flow (MBF). AIM: The aim of this study was to assess the impact of revascularization on MBF and myocardial flow reserve (MFR) assessed with 15 O-water PET and invasive flow and pressure measurements. METHODS: In 21 patients with single-vessel disease referred for percutaneous coronary intervention (PCI), serial PET perfusion imaging and fractional flow reserve (FFR), coronary flow reserve (CFR) and index of microcirculatory resistance (IMR) were performed during PCI and after 3 months. RESULTS: In the affected myocardium, stress MBF and MFR increased significantly from before revascularization to 3 months after revascularization: stress MBF 2.4 ±â€…0.8 vs. 3.2 ±â€…0.8; P  < 0.001 and MFR 2.5 ±â€…0.8 vs. 3.4 ±â€…1.1; P  = 0.004. FFR and CFR increased significantly from baseline to after revascularization and remained stable from after revascularization to 3-month follow-up: FFR 0.64 ±â€…0.20 vs. 0.91 ±â€…0.06 vs. 0.91 ±â€…0.07; P  < 0.001; CFR 2.4 ±â€…1.2 vs. 3.6 ±â€…1.9 vs. 3.6 ±â€…1.9; P  < 0.001, whereas IMR did not change significantly: 30.3 ±â€…22.9 vs. 30.1 ±â€…25.3 vs. 31.9 ±â€…25.2; P  = ns. After revascularization, an increase in stress MBF was associated with an increase in FFR ( r  = 0.732; P  < 0.001) and an increase in MFR ( r  = 0.499; P  = 0.021). IMR measured before PCI was inversely associated with improvement in stress MBF, ( r  = -0.616; P  = 0.004). CONCLUSION: Recovery of myocardial perfusion after PCI was associated with an increase in FFR 3 months after revascularization. Microcirculatory dysfunction was associated with less improvement in myocardial perfusion.


Assuntos
Angina Estável , Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Humanos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Angiografia Coronária/métodos , Microcirculação/fisiologia , Intervenção Coronária Percutânea/efeitos adversos , Angina Estável/diagnóstico por imagem , Angina Estável/terapia , Angina Estável/etiologia , Água , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/etiologia
3.
Catheter Cardiovasc Interv ; 103(2): 276-285, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38091338

RESUMO

BACKGROUND: Patients with acute coronary syndromes (ACS) may have worse outcomes after percutaneous coronary intervention compared to patients without ACS. AIMS: To compare 5-year efficacy and safety outcomes in patients with and without ACS treated with biodegradable polymers, the ultrathin strut sirolimus-eluting Orsiro stent (O-SES) or the biolimus-eluting Nobori stent (N-BES). METHODS: The Scandinavian Organisation for Randomized Trials with Clinical Outcome VII is a randomized trial comparing O-SES and N-BES in an all-comer setting. Of 2525 patients, 1329 (53%) patients had ACS and 1196 (47%) patients were without ACS. Endpoints were target lesion failure (TLF) (a composite of cardiac death, target lesion myocardial infarction, or target lesion revascularization) and definite stent thrombosis within 5 years. RESULTS: At 5-year follow-up, TLF did not differ significantly between patients with and without ACS (12.3% vs. 13.2%; rate ratio (RR) 1.00; 95% confidence interval (CI): 0.70-1.44), whereas the risk of definite stent thrombosis was increased in patients with ACS (2.3% vs. 1.3; RR: 2.01 [95% CI: 1.01-3.98]). In patients with ACS, the rate of TLF was similar between O-SES and N-BES (12.4% vs. 12.3%; RR: 1.02; 95% CI: 0.74-1.40). The reduced risk of definite stent thrombosis in O-SES treated ACS patients within the first year (0.2% vs. 1.6%; RR: 0.12; 95% CI: 0.02-0.93) was not maintained after 5 years (1.8% vs. 2.7%; RR: 0.77; 95% CI: 0.37-1.63). CONCLUSION: Patients with ACS had an increased risk of stent thrombosis regardless of the stent type used. Long-term outcomes were similar for ACS patients treated with O-SES or N-BES at 5 years.


Assuntos
Síndrome Coronariana Aguda , Ácidos Alcanossulfônicos , Fármacos Cardiovasculares , Doença da Artéria Coronariana , Trombose Coronária , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/terapia , Síndrome Coronariana Aguda/complicações , Fatores de Risco , Resultado do Tratamento , Stents Farmacológicos/efeitos adversos , Implantes Absorvíveis , Desenho de Prótese , Fármacos Cardiovasculares/efeitos adversos , Trombose Coronária/etiologia , Stents/efeitos adversos , Polímeros , Intervenção Coronária Percutânea/efeitos adversos
4.
Eur Heart J Case Rep ; 7(7): ytad307, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37485290

RESUMO

Background: Pulmonary embolism (PE) is common, and it is the third leading cause of cardiovascular death. The management of patients with high-risk PE generally consists of systemic thrombolysis; however, surgical or catheter-directed treatment (CDT) can be considered in selected cases. Case summary: A 78-year-old female patient presenting with acute severe dyspnoea develops out-of-hospital cardiac arrest (OHCA). She was admitted with return of spontaneous circulation and a critical haemodynamic state upon arrival to the catheterization laboratory with an estimated no-flow time of 1 min and low-flow time of 52 min. An acute pulmonary angiogram reveals massive PE. After a PE response team conference, the patient was not found eligible for extracorporeal membrane oxygenation, surgery, or thrombolysis. The patient was treated with catheter-directed mechanical thrombectomy 129 min after first medical contact. The patient recovered and was discharged without any neurological deficits. Discussion: Catheter-directed mechanical thrombectomy was a successful treatment in a patient with OHCA secondary to high-risk PE, where thrombolysis and surgical interventions were considered contraindicated. This case underlines the future perspectives of CDT and also that a multidisciplinary team approach may benefit patients with high-risk PE.

5.
Cardiol Res Pract ; 2023: 3197512, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37361000

RESUMO

Background: Reversible P2Y12 inhibition can be obtained with cangrelor administered intravenously. More experience with cangrelor use in acute PCI with unknown bleeding risk is needed. Objectives: To describe real-world use of cangrelor including patient and procedure characteristics and patient outcomes. Methods: We performed a single-centre, retrospective, and observational study including all patients treated with cangrelor in relation to percutaneous coronary intervention at Aarhus University Hospital during the years 2016, 2017, and 2018. We recorded procedure indication and priority, the indications for cangrelor use, and patient outcomes within the first 48 hours after initiation of cangrelor treatment. Results: We treated 991 patients with cangrelor in the study period. Of these, 869 (87.7%) had an acute procedure priority. Among acute procedures, patients were mainly treated for STEMI (n = 723) and the remaining were treated for cardiac arrest and acute heart failure. Use of oral P2Y12 inhibitors prior to percutaneous coronary intervention was rare. Fatal bleeding events (n = 6) were only observed among patients undergoing acute procedures. Stent thrombosis was observed in two patients receiving acute treatment for STEMI. Thus, cangrelor can be used in relation to PCI under acute circumstances with advantages in terms of clinical management. The benefits and risks, in terms of patient outcomes, should ideally be assessed in randomized trials.

6.
Cardiovasc Revasc Med ; 54: 41-46, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37045636

RESUMO

BACKGROUND: The relation between the resting full cycle ratio (RFR) and fractional flow reserve (FFR) is not fully understood. This study aims to investigate the influence of coronary microvascular dysfunction, assessed by the index of microvascular resistance (IMR), on RFR compared to FFR in patients undergoing functional assessment for coronary stenosis. MATERIALS AND METHODS: Two-hundred patients with borderline stenosis underwent functional assessment of RFR, FFR, coronary flow reserve (CFR) and IMR. Retriever operator curve analysis was performed to assess the diagnostic value of RFR in patients with (IMR ≥ 24) and (IMR < 24). RESULTS: Median RFR did not differ significantly in patients with IMR ≥ 24 compared to patients with IMR < 24: 0.89 (interquartile range (IQR) 0.84, 0.95) vs. 0.90 (IQR 0.84, 0.92), p = 0.29). FFR was significantly higher in patients with IMR ≥ 24 compared to patients with IMR < 24: median FFR 0.85 (IQR (0.76, 0.92)) vs. 0.82 (IQR 0.73, 0.86), p = 0.009, and median CFR was significantly lower 1.80 (IQR 1.40, 2.55) vs. 2.70 (IQR 1.80, 3.95), p < 0.001. The diagnostic value of RFR was high (Area under the curve (AUC) 0.89 95 % Confidence Interval: [0.85, 0.93]) and AUC did not differ between patients with IMR ≥ 24 compared to patients with IMR < 24: 0.89 vs. 0.90, p = 0.89. An overall optimal cut off of 0.88 was identified. The cut off did not differ significantly between patients with IMR ≥ 24 compared to patients with IMR < 24: 0.88 vs. 0.90, p = 0.397. CONCLUSION: In patients with coronary borderline stenosis, the coronary microvascular function did not influence on the cut off values or AUC of RFR compared to FFR.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Constrição Patológica , Angiografia Coronária , Microcirculação , Resistência Vascular , Vasos Coronários/diagnóstico por imagem , Valor Preditivo dos Testes , Estenose Coronária/diagnóstico por imagem , Cateterismo Cardíaco
7.
Circ Cardiovasc Interv ; 16(1): e012332, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36649389

RESUMO

BACKGROUND: Biodegradable polymer drug-eluting stents were developed to improve safety and efficacy outcomes for patients undergoing percutaneous coronary intervention. However, few long-term follow-up efficacy studies are available. The study sought to investigate 5-year results from the SORT OUT VII trial (Scandinavian Organization for Randomized Trials With Clinical Outcome) comparing the biodegradable polymer ultrathin-strut sirolimus-eluting Orsiro stent (O-SES) versus the biodegradable polymer biolimus-eluting Nobori stent (N-BES). METHODS: This registry-based, randomized, multicenter, single-blinded, noninferiority trial compared O-SES and N-BES in an all-comer population. The composite primary end point, target lesion failure, consisted of cardiac death, myocardial infarction related to the target lesion, or target lesion revascularization within 1 year. Follow-up was extended to 5 years. RESULTS: Five-year follow-up was completed for 2521 patients (99.8%). Five-year target lesion failure did not differ between O-SES (12.4%) and N-BES (13.1%; rate ratio [RR], 0.94 [95% CI, 0.75-1.18]). Cardiac death (RR, 0.95 [95% CI, 0.67-1.34]), target myocardial infarction (RR, 1.14 [95% CI, 0.76-1.71]), target lesion revascularization (RR, 0.90 [95% CI, 0.67-1.21]), and definite stent thrombosis rates (RR, 0.73 [95% CI, 0.41-1.33]) did not differ significantly between the 2 stents. Within the first year, definite ST was significantly lower for O-SES (0.4%) compared to N-BES (1.2%; RR, 0.33 [95% CI, 0.12-0.92]), but no difference was from 1 through 5 years: O-SES 1.2% and N-BES 0.9% (RR, 1.28 [95% CI, 0.58-2.82]). CONCLUSIONS: Five years after treatment with biodegradable polymer stents, target lesion failure did not differ among O-SES and N-BES. Definite stent thrombosis was less often seen within the first year in the O-SES but the difference was not maintained after 5 years. REGISTRATION: URL: https://clinicaltrials.gov; Unique identifier: NCT01879358.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Sirolimo/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Fatores de Risco , Resultado do Tratamento , Implantes Absorvíveis , Infarto do Miocárdio/etiologia , Polímeros , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese
8.
Ugeskr Laeger ; 184(34)2022 08 22.
Artigo em Dinamarquês | MEDLINE | ID: mdl-36065861

RESUMO

Patients with chronic total occluded coronary arteries (CTO) have worse prognosis than patients who do not have CTO. Medical therapy before embarking on invasive treatment is recommended. Invasive management with percutaneous coronary intervention or coronary artery bypass grafting is reserved for patients who receive medical treatment and have resistant angina and reversible ischaemia. Treatment should always be decided in collaboration with the patient, cardiologists, and cardio-thoracic surgeons. Follow-up treatment in the primary sector should include cardiac rehabilitation and reconsideration of medical therapy.


Assuntos
Vasos Coronários , Intervenção Coronária Percutânea , Doença Crônica , Angiografia Coronária , Ponte de Artéria Coronária/efeitos adversos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento
9.
Catheter Cardiovasc Interv ; 99(4): 1095-1103, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35043539

RESUMO

This sub-study of the SORT OUT IX trial sought to compare clinical outcomes between patients with diabetes randomized to implantation of either the polymer-free biolimus A9-coated BioFreedom stent (BF-BES) or the ultra-thin strut, biodegradable polymer sirolimus-eluting Orsiro stent (O-SES). Patients with diabetes have an increased risk of target lesion failure (TLF) after percutaneous coronary intervention (PCI). The impact of different stent types in patients with diabetes is still discussed. A total of 607 of the 3151 patients (19.3%) enrolled in the SORT OUT IX study had diabetes. Randomization was stratified by patients with/without diabetes; 304 received BF-BES and 303 O-SES. The primary endpoint was TLF, which was a composite of cardiac death, myocardial infarction (not related to other than the index lesion) and target lesion revascularization (TLR) within 1 year. After 1 year, patients with diabetes had higher TLF (7.2% vs. 3.7%, incidence rate ratio [IRR]: 1.65; 95% confidence interval [CI]: 1.08-2.50), than patients without diabetes. TLF did not differ significantly between BF-BES and O-SES in patients with diabetes (8.2% vs. 6.3%, IRR: 1.17; 95% CI: 0.63-2.20). In patients with diabetes, cardiac death occurred in 2.3% of BF-BES and in 3.6% of O-SES (IRR: 0.58; 95% CI: 0.23-1.45) and TLR occurred in 5.3% and 2.3% of BF-BES and O-SES, respectively (IRR: 2.12; 95% CI: 0.81-5.56). Definite stent thrombosis rates of 1.3% were found in both stent types. Patients with diabetes had higher 1-year TLF rate after PCI compared to patients without diabetes, whereas TLF did not differ significantly between the two stent types BF-BES and O-SES in patients with diabetes.


Assuntos
Doença da Artéria Coronariana , Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea , Implantes Absorvíveis , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/etiologia , Doença da Artéria Coronariana/terapia , Morte , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Polímeros , Desenho de Prótese , Stents , Resultado do Tratamento
10.
Cardiovasc Revasc Med ; 40: 101-110, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34949544

RESUMO

BACKGROUND: The purpose of a bioresorbable scaffold (BRS) is to provide radial support during coronary healing. In this study, coronary artery healing after optical coherence tomography (OCT)- versus angiography-guided magnesium BRS (MBRS) implantation in patients with non-ST-segment-elevation myocardial infarction (NSTEMI) is compared. METHODS: 75 patients were randomized 1:1 to OCT- or angiography-guided implantation of a MBRS with protocolled pre- and post-dilation. In the OCT-guided group, prespecified criteria indicating additional intervention were (1) scaffold under-expansion, (2) strut malapposition, (3) edge dissection, and (4) residual stenosis at distal or proximal reference segments. The primary endpoint was OCT-derived healing stage at 6 months. RESULTS: At 6 months, there was no difference in average healing stage between OCT- and angiography-guided intervention (4.6 [interquartile range (IQR): 4.5-4.7] versus 4.5 [IQR: 4.3-4.7]; p = 0.54). The MBRSs were completely resolved in 77.0% [IQR: 68.5-85.5] versus 76.5% [IQR: 67.9-85.5]; (p = 0.97). Minimal lumen area (MLA) was reduced at 6 months in both the OCT- (32.3%; p < 0.01) and the angiography-guided group (21.3%; p < 0.01), however OCT-guided implantation was associated with a greater reduction of total lumen volume (-27.1 ± 32.5 mm3 versus -5.0 ± 32.9 mm3; p < 0.01) and MLA (-2.3 ± 1.6 mm2 vs. -1.4 ± 1.4 mm2; p = 0.02). CONCLUSIONS: In NSTEMI patients, OCT-guidance with protocolled pre- and post-dilation of MBRS implantation showed similar healing pattern at 6 months compared to angiography-guidance alone. CLINICAL TRIAL REGISTRATION: The Coronary Artery Healing Process after Optical Coherence Tomography Guided Percutaneous Coronary Intervention with Magmaris Bioresorbable Scaffold in Patients with Non-ST-Segment-Elevation Myocardial Infarction: (HONEST) trial is registered with ClinicalTrials.gov, NCT03016624.


Assuntos
Infarto do Miocárdio sem Supradesnível do Segmento ST , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Implantes Absorvíveis , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Magnésio , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio sem Supradesnível do Segmento ST/terapia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Desenho de Prótese , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento
11.
Eur Heart J Cardiovasc Imaging ; 23(11): 1511-1519, 2022 10 20.
Artigo em Inglês | MEDLINE | ID: mdl-34661645

RESUMO

AIMS: The aim of this study was to evaluate the association between coronary computed tomography angiography (CCTA)-derived fractional flow reserve (FFRCT) and recurrent chest pain (CP) at 1-year follow-up in patients with stable angina pectoris (SAP). METHODS AND RESULTS: Study of patients (n = 267) with SAP who underwent CCTA and FFRCT testing; 236 (88%) underwent invasive coronary angiography; and 87 (33%) were revascularized. Symptomatic status at 1-year follow-up was gathered by a structured interview. Three different FFRCT algorithms were applied using the following criteria for abnormality: (i) 2 cm-FFRCT ≤0.80; (ii) d-FFRCT ≤0.80; and (iii) a combination in which both a d-FFRCT ≤0.80 and a ΔFFRCT ≥0.06 must be present in the same vessel (c-FFRCT). Patients were classified into two groups based on the FFRCT test result and revascularization: completely revascularized/normal (CRN), patients in whom all coronary arteries with an abnormal FFRCT test result were revascularized or patients with completely normal FFRCT test results, and incompletely revascularized (IR), patients in whom ≥1 coronary artery with an abnormal FFRCT test result was not revascularized. Recurrent CP was present in 62 (23%) patients. Classification of patients (CRN or IR) was significantly associated with recurrent CP for all applied FFRCT interpretation algorithms. When applying the c-FFRCT algorithm, the association with recurrent CP was found, irrespective of the extent of coronary calcification and the degree of coronary stenosis. A negative association between per-patient minimal d-FFRCT and recurrent CP was demonstrated, P < 0.005. CONCLUSION: An abnormal FFRCT test result is associated with an increased risk of recurrent CP in patients with new-onset SAP.


Assuntos
Angina Estável , Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Angiografia Coronária/métodos , Angiografia por Tomografia Computadorizada/métodos , Angina Estável/diagnóstico por imagem , Doença da Artéria Coronariana/complicações , Valor Preditivo dos Testes , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/complicações , Vasos Coronários , Índice de Gravidade de Doença
12.
Circ Cardiovasc Qual Outcomes ; 14(6): e007302, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34078097

RESUMO

BACKGROUND: In coronary artery bypass grafting (CABG), the use of fractional flow reserve (FFR) is insufficiently investigated. Stenosis assessment usually relies on visual estimates of lesion severity. This study evaluated health-related quality of life (HRQoL) and angina after FFR- versus angiography-guided CABG. METHODS: One hundred patients referred for CABG were randomized to FFR- or angiography-guided CABG. In the FFR group, lesions with FFR>0.80 were deferred, while the surgeon was blinded to the FFR values in the angiography group. Before and 6 months after CABG, HRQoL was assessed by the health state classifier EQ-5D of the EuroQoL 5-level instrument and angina status based on the Canadian Cardiovascular Society classification system were registered. RESULTS: Six-month angiography included FFR evaluations of deferred lesions. In total, completed EQ-5D of the EuroQoL 5-level instrument questionnaires were available in 86 patients (43 in the FFR versus 43 in the angiography-guided group). HRQoL was significantly improved and angina significantly decreased from baseline to 6 months after CABG with no difference between the randomization groups. Graft failure rates and clinical outcomes were similar in both groups. Patients with graft failure or FFR<0.80 of the previous deferred lesions had significantly lower visual analogue scale scores (78.7±14.2 versus 86.8±14.7, P=0.004) and more angina compared with patients without graft failure or FFR≥0.80 at 6-month follow-up. CONCLUSIONS: FFR- versus angiography-guided CABG demonstrated similar improvements in HRQoL and angina 6 months after CABG. Graft failure or low FFR in deferred lesions were associated with low HRQoL and angina. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02477371.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Trialato , Canadá , Angiografia Coronária , Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Humanos , Qualidade de Vida , Distribuição Aleatória , Resultado do Tratamento
13.
Cardiovasc Revasc Med ; 30: 50-58, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33012685

RESUMO

OBJECTIVES: To compare the early vascular healing of ruptured plaques (RP) and non-ruptured plaques (NRP) one month after primary percutaneous coronary intervention (PCI) in patients with ST-segment elevation myocardial infarction (STEMI), using optical coherence tomography (OCT). BACKGROUND: Vascular healing and strut coverage are important factors in reducing the risk of stent thrombosis after PCI. Influence of underlying lesion characteristics and differences in healing response between RP and NRP are unknown. METHODS: Twenty-six STEMI-patients underwent PCI and implantation of a polymer-free drug-coated Biofreedom stent (BF-BES). OCT was performed pre-PCI, post-PCI and at 1-month follow-up. The patients were divided into two groups: RP = 15 and NRP = 11. OCT analyses of culprit lesion, post stent implantation at baseline and follow-up were performed to determine the difference in vascular healing based on presence of uncovered and/or malapposed stent struts and intraluminal filling defects. RESULTS: The stent coverage did not differ significantly between the two groups at 1-month follow-up with percentage of uncovered struts: RP 26.5% [IQR 15.0-49.0] and NRP 28.1% [IQR 15.5-38.8] for NRP (p = 0.78). At 1-month, RP showed an increased percentage of late acquired malapposed struts (1.4% [IQR 0.8-2.4] vs. 0.0% [IQR 0.0-1.4], p = 0.03) and a larger total malapposition area (1.3 mm2 [IQR 0.4-2.5] vs. 0.0 mm2 [IQR 0.0-0.9], p = 0.01), compared to NRP. CONCLUSION: Three out of four struts were covered within one month after stenting. The vascular healing was comparable in RP and NRP on stent coverage. However, RP had more and larger late acquired malapposition areas.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Placa Aterosclerótica , Infarto do Miocárdio com Supradesnível do Segmento ST , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Tomografia de Coerência Óptica , Resultado do Tratamento
14.
Circulation ; 141(25): 2052-2063, 2020 06 23.
Artigo em Inglês | MEDLINE | ID: mdl-32434381

RESUMO

BACKGROUND: In patients with increased bleeding risk, the biolimus A9-coated BioFreedom stent, a stainless steel drug-coated stent free from polymer, has shown superiority compared with a bare-metal stent. The aim of this study was to investigate whether the BioFreedom stent is noninferior to a modern ultrathin strut biodegradable polymer cobalt-chromium sirolimus-eluting Orsiro stent in an all-comers patient population treated with percutaneous coronary intervention. METHODS: The SORT OUT IX trial (Scandinavian Organization for Randomized Trials With Clinical Outcome IX), was a large-scale, registry-based, randomized, multicenter, single-blind, 2-arm, noninferiority trial. The primary end point, major adverse cardiovascular events, was defined as the composite of cardiac death, myocardial infarction not related to any segment other than the target lesion, or target lesion revascularization within 1 year, analyzed by intention-to-treat. The trial was powered to assess noninferiority for major adverse cardiovascular events of the BioFreedom stent compared with the Orsiro stent with a predetermined noninferiority margin of 0.021. RESULTS: Between December 14, 2015 and April 21, 2017, 3151 patients were assigned to treatment with the BioFreedom stent (1572 patients, 1966 lesions) or to the Orsiro stent (1579 patients, 1985 lesions). Five patients were lost to follow-up because of emigration (99.9% follow-up rate). Mean age was 66.3±10.9, diabetes mellitus was seen in 19.3% of patients, and 53% of the patients had acute coronary syndromes. At 1 year, intention-to-treat analysis showed that 79 (5.0%) patients, who were assigned the BioFreedom stent, and 59 (3.7%), who were assigned the Orsiro stent, met the primary end point (absolute risk difference 1.29% [upper limit of one-sided 95% CI 2.50%]; Pnoninferiority=0.14). Significantly more patients in the BioFreedom stent group had target lesion revascularization than those in the Orsiro stent group (55 [3.5%] vs 20 [1.3%], rate ratio 2.77 [95% CI, 1.66-4.62]; P<0.0001). CONCLUSIONS: The biolimus A9-coated BioFreedom polymer-free stent did not meet criteria for noninferiority for major adverse cardiovascular events at 12 months when compared with the ultrathin strut biodegradable polymer sirolimus-eluting Orsiro stent in an all-comers population Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02623140.


Assuntos
Implantes Absorvíveis , Anti-Inflamatórios , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/efeitos adversos , Polímeros , Sirolimo/análogos & derivados , Idoso , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/etiologia , Stents Farmacológicos/efeitos adversos , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
15.
Trials ; 21(1): 415, 2020 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-32446298

RESUMO

BACKGROUND: Treatment with beta-blockers is currently recommended after myocardial infarction (MI). The evidence relies on trials conducted decades ago before implementation of revascularization and contemporary medical therapy or in trials enrolling patients with heart failure or reduced left ventricular ejection fraction (LVEF ≤ 40%). Accordingly, the impact of beta-blockers on mortality and morbidity following acute MI in patients without reduced LVEF or heart failure is unclear. METHODS/DESIGN: The Danish trial of beta-blocker treatment after myocardial infarction without reduced ejection fraction (DANBLOCK) is a prospective, randomized, controlled, open-label, non-blinded endpoint clinical trial designed to evaluate the efficacy of beta-blocker treatment in post-MI patients in the absence of reduced LVEF or heart failure. We will randomize 3570 patients will be randomized within 14 days of index MI to beta-blocker or control for a minimum of 2 years. The primary endpoint is a composite of all-cause mortality, recurrent MI, acute decompensated heart failure, unstable angina pectoris, or stroke. The primary composite endpoint will be assessed through locally reported and adjudicated endpoints supplemented by linkage to the Danish national registers. A number of secondary endpoints will be investigated including patient reported outcomes and cardiovascular mortality. Data from similar ongoing trials in Norway and Sweden will be pooled to perform an individual patient data meta-analysis. DISCUSSION: DANBLOCK is a randomized clinical trial investigating the effect of long-term beta-blocker therapy after myocardial infarction in patients without heart failure and reduced LVEF. Results from the trial will add important scientific evidence to inform future clinical guidelines. TRIAL REGISTRATION: Clinicaltrials.gov, NCT03778554. Registered on 19 December 2018. European Clinical Trials Database, 2018-002699-42, registered on 28 September 2018.


Assuntos
Antagonistas Adrenérgicos beta/uso terapêutico , Infarto do Miocárdio/tratamento farmacológico , Volume Sistólico , Administração Oral , Antagonistas Adrenérgicos beta/administração & dosagem , Causas de Morte , Ensaios Clínicos Fase IV como Assunto , Dinamarca , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/fisiopatologia , Humanos , Estudos Multicêntricos como Assunto , Infarto do Miocárdio/complicações , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/prevenção & controle , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto , Prevenção Secundária/métodos , Resultado do Tratamento , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/fisiopatologia
16.
Cardiovasc Revasc Med ; 21(10): 1237-1243, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32247563

RESUMO

The diagnostic accuracy of non-invasive diagnostic methods for detecting coronary artery disease has increased in recent years. This study aimed to assess the diagnostic performance of 15O-water positron emission tomography (PET) in terms of stress myocardial blood flow (MBF) and myocardial flow reserve (MFR) in patients with single-vessel disease referred for percutaneous coronary intervention (PCI), using fractional flow reserve (FFR) value of ≤0.80 as the reference for a significant stenosis. We also assessed the influence of the index of microcirculatory resistance (IMR) on the diagnostic performance of PET. 15O-water PET FFR and IMR were measured before PCI in 26 patients with single-vessel disease. Stress MBF < 2.5 ml/min/g (95% confidence interval [CI]) had sensitivity 78% (95% CI: 52%-94%), specificity 50% (95% CI: 16%-84%), positive predictive value (PPV) 78% (95% CI: 63%-88%), negative predictive value (NPV) 50% (95% CI: 25%-75%), and accuracy 69% (95% CI: 48%-86%). MFR < 2.5 had sensitivity 72% (95% CI: 47%-90%), specificity 75% (95% CI: 35%-97%), PPV 87% (95% CI: 65%-96%), NPV 55% (95% CI: 34%-74%), and accuracy 73% (95% CI: 52%-88%). In patients with IMR > 24, stress MBF correlated with FFR (r = 0.651; p = 0.016) whereas stress MBF did not correlate with FFR in patients with IMR < 24. In conclusion, stress MBF and MFR had modest diagnostic performance compared to invasive FFR measurements in patients with single-vessel disease.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Isquemia Miocárdica , Imagem de Perfusão do Miocárdio , Intervenção Coronária Percutânea , Angiografia Coronária , Estenose Coronária , Humanos , Microcirculação , Tomografia por Emissão de Pósitrons , Valor Preditivo dos Testes , Água
19.
JACC Cardiovasc Interv ; 12(7): 624-633, 2019 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-30947936

RESUMO

OBJECTIVES: The aim of this study was to compare the thin-strut biodegradable-polymer everolimus-eluting platinum-chromium stent (EES) with the biodegradable-polymer biolimus-eluting stainless-steel stent (BES). BACKGROUND: Currently available drug-eluting coronary stents have been refined to reduce the risk for coronary events following implantation. METHODS: This randomized, multicenter, all-comers, noninferiority trial was undertaken at 3 sites in western Denmark. Patients with clinical indications for percutaneous coronary intervention were eligible for inclusion. Patients were randomly assigned (1:1) to either EES or BES. The primary endpoint, target lesion failure, was a composite of safety (cardiac death and myocardial infarction not clearly attributable to a nontarget lesion) and efficacy (target lesion revascularization) at 12 months, analyzed using intention-to-treat principles. The trial was powered to assess target lesion failure noninferiority of the EES compared with the BES with a predetermined noninferiority margin of 3%. RESULTS: A total of 1,385 patients were assigned to treatment with EES and 1,369 patients to treatment with BES. The analysis showed that 55 patients (4.0%) assigned to the EES and 60 (4.4%) assigned to the BES met the primary endpoint (absolute risk difference 0.4%; upper limit of 1-sided 95% confidence interval: 1.7%; p < 0.001). CONCLUSIONS: At 1-year follow-up, the EES was found to be noninferior to the BES with respect to target lesion failure. (Everolimus-eluting SYNERGY Stent Versus Biolimus-Eluting Biomatrix NeoFlex Stent-SORT-OUT VIII; NCT02093845).


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Everolimo/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Polímeros/química , Sirolimo/análogos & derivados , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Dinamarca , Everolimo/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
20.
Catheter Cardiovasc Interv ; 93(4): 567-573, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30244533

RESUMO

OBJECTIVES: In this substudy of the SORT OUT VII trial, the clinical outcomes among patient with diabetes mellitus treated with Orsiro sirolimus-eluting stent (O-SES; Biotronik, Bülach, Switzerland) or Nobori biolimus-eluting stent (N-BES; Terumo, Tokyo, Japan) were compared. BACKGROUND: Diabetes is associated with increased risk of target lesion failure (TLF) after percutaneous coronary intervention. METHODS: In total, 2525 patients were randomized to stent implantation with O-SES (n = 1261, diabetes: n = 236) or N-BES (n = 1264, diabetes: n = 235). The primary endpoint, TLF, was a composite of cardiac death, target-lesion myocardial infarction (MI), or target lesion revascularization (TLR) within 2 years. RESULTS: At 2 year, TLF did not differ between O-SES vs N-BES in diabetic (9.3% vs 9.4%; RR 0.98, 95% CI 0.54-1.78) patients. The individual components of the primary endpoint did not differ among stent type. In diabetics, cardiac death occurred in 3% of O-SES-treated and in 3.8% of N-BES-treated patients (RR 0.77, 95% CI 0.29-2.08), MI occurred in 3.0% of O-SES-treated and in 3.8% of N-BES-treated patients (RR 0.76, 95% CI 0.28-2.06) and TLR occurred in 5,5% of O-SES-treated and in 6.0% of N-BES-treated patients (RR 0.91, 95% CI 0.43-1.95). CONCLUSION: TLF did not differ between O-SES- and N-BES-treated diabetic patients.


Assuntos
Implantes Absorvíveis , Síndrome Coronariana Aguda/terapia , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Polímeros , Sirolimo/análogos & derivados , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/mortalidade , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Medição de Risco , Fatores de Risco , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...